Underground Wiring
If you plan to run charged wire underground from your fence charger to the fence line you must install it properly using the correct material or your fence will be "grounded out".
- DO NOT use standard insulated wiring such as Romex, etc. for underground wiring.
- DO NOT use underground wiring by itself.
- DO use
Baygard item #693 insulated underground wire specifically designed for high voltage electric fence. Underground wire
MUST BE insulated for a minimum of 15,000 volts.
Baygard item #693 is
insulated to 20,000 volts is an excellent choice.
- DO run underground wire through PVC (plastic) conduit. Bring both ends of conduit a minimum of 6" above ground level. Caulk both ends of conduit so that water cannot enter conduit.
 
 
|